Jinko Solar-Integrated PV-Storage Solutions for Manufacturing Plants | Cement Plant

Jinko Energy

Integrated PV-Storage Solutions for Manufacturing Plants | Cement Plant

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookies Policy.

Accept
English

Integrated PV-Storage Solutions
for Manufacturing Plants

Textile Manufacturing
Cement Plant
Steel Mill

Description and Typical Load Characteristics

A manufacturing facility that is a high-voltage dedicated transformer user operating at 10 kV or higher. Production loads are significantly higher during daytime hours and on weekdays than at night or on holidays. This is one of the scenarios where the “rooftop PV + customer-side energy storage” model offers the greatest economic viability, featuring a high proportion of self-consumed PV power, while energy storage can be used for peak-valley arbitrage, demand response, and distribution capacity relief.

Load Curve

High load during daytime on weekdays, baseline load maintained at night, and reduced load on weekends and holidays.

Key Equipment

Production lines, electric motors, air compressors, kilns/heating equipment, cooling systems, air conditioning, circulation pumps, plant utility systems.

Electricity Consumption Patterns

Highly correlated with production schedules, with distinct peaks in the morning and afternoon; electricity consumption is even higher during high summer temperatures.

Billing Characteristics

Primarily dual rate structures, demand charges or capacity charges have a significant impact on billing statements.

  • Pressure from Electricity Prices

    Electricity costs account for a significant portion of manufacturing costs, and peak-hour and super-peak electricity rates have a major impact on production costs.

  • Losses Caused by Power Outage

    Power rationing or load shedding disrupts continuous production, and the losses from production line downtime may far exceed the electricity costs themselves.

  • High Cost for Capacity Expansion

    Short-term load spikes may lead to insufficient transformer capacity; capacity expansion involves long lead times and high investment costs.

  • PV-storage Mismatch

    Although rooftop space is abundant, PV output does not perfectly align with production loads; energy storage is needed to improve grid integration and maximize returns.

Standardized Design for PV and Energy Storage Capacity

  • 01. PV Capacity

    60 MWp (ground-mounted PV project, annual power generation of 66 million kWh)

  • 02. Energy Storage Capacity

    10MW / 20MWh

  • 03. Control System

    The EMS integrates PV, energy storage, main transformer loads, production schedules, and time-of-use electricity rates to achieve demand response.

Charging and Discharging

Charge during off-peak electricity rate periods (e.g., at night) to reduce electricity purchase costs.

Off-Peak Charging

Discharge stored energy during peak electricity rate periods to replace high-cost grid purchases.

Peak-Hour Discharging

Make appropriate adjustments during off-peak periods based on production load requirements; prioritize solar power to meet the load, and feed excess electricity into the energy storage system.

Off-Peak Regulation

When the main transformer load approaches the demand threshold, the energy storage system enters demand control mode to limit peak demand and reduce demand-based electricity charges.

Demand Control

In the event of a grid failure or power rationing, the energy storage system can quickly switch to off-grid mode to provide uninterrupted power to critical loads.

Off-Grid Protection

Economic Benefits

Cost Reduction and Efficiency Improvement

Reduce electricity costs through peak-off-peak arbitrage and demand management.

Green Energy Consumption

Increase the self-consumption rate of solar power to over 90% to avoid curtailment.

Grid Stability

Mitigate load fluctuations and improve power quality

Emergency Suppor

Ensure uninterrupted power supply to critical production loads during grid failures or power rationing.

Tiger Neo 3.0 — Seven Core Advantages

01. Ultra-high power

front power output reaches 670 W with a conversion efficiency of 24.8%. Boasting power and efficiency far above industry benchmarks, these modules generate more electricity per square meter of rooftop area, making them ideal for manufacturing factories with limited roof space.

02. Ultra-high bifaciality

bifaciality of 85%±5%, exceeding the national standard requirement of 75%. The modules efficiently capture ground-reflected light and ambient scattered light to greatly boost overall power generation.

03. Excellent temperature coefficient (-0.26%/°C)

maintains stable power generation performance under high‑temperature conditions. Manufacturing factory rooftops get extremely hot in summer, and Tiger Neo 3.0 suffers less power degradation at high temperatures to guarantee steady power output.

04. Ultra-low annual degradation (only -0.35%)

the first-year degradation rate is 1%, followed by an annual degradation rate of merely 0.35%, securing power generation revenue throughout its 30-year service life.

05. Strong low-irradiance performance

the modules perform excellently under low irradiance conditions such as cloudy days, dawn and dusk, delivering a power generation gain of over 4%.

06. Maximum safety

certified Class A under stringent IEC and UL standards, representing the highest fire resistance level in the photovoltaic industry.

07. Protection against extreme weather

hail resistance up to 55 mm, with a rear wind load capacity of -5000 Pa. Adaptable to extreme climates, it outperforms the common industry standard of 2400 Pa for wind load resistance.

Integrated PV-Storage Solutions
for Manufacturing Plants

Industry-leading Safety Performance

  • Material-level Thermal Isolation
  • Electrical-grade Armored Protection
  • Multi-sensor Integrated Rapid Fire Suppression
  • Full-stack Early Warning

Recommended Products

66 QL6-BDV

Bifacial Module

Learn More

SunGiga G2

Liquid Cooling ESS Solution

Learn More

SunGiga G2 Plus

Liquid Cooling ESS Solution

Learn More
↑
All rights reserved © 2026 Jinko Solar. 沪ICP备2022022315号-1. Privacy Policy. Powered by Webfoss.